Ballasted Clarification Technology Provides Low Cost Solution that Meets Phosphorus Limits

CoMag system exceeds performance parameters while providing high-quality effluent

Challenge

Prior to 2007, the Concord, Massachusetts wastewater treatment plant operated under a NPDES permit that allowed a seasonal phosphorus limit of 0.7 mg/L.  However, with the issuance of a new five-year permit with a phosphorus limit of 0.2 mg/L and the probability that future limits could reach as low as 0.05 mg/L, the city of Concord needed a treatment solution that would be reliable and cost-effective over the long term.

 

Solution

​When compared to dissolved air floatation, media filtration and sand ballasted technologies, Concord’s consulting engineers recommended the CoMag® System​ from Evoqua Water Technologies. Key benefits include:

  • Ability to provide effluent TP values from 0.2 mg/L to ≤ 0.05 mg/L simply by adjusting the flocculent dose.

  • Reliability of operation — conventional flocculation and coagulation coupled with high rate clarification and no filters to clog or backwash.

  • Capital cost savings given its small clarifiers and footprint.


The CoMag® System Overview

Simple, reliable and proven, the CoMag® System from Evoqua uses magnetite to ballast conventional chemical floc, enhancing settling rates to dramatically increase the performance of wastewater treatment facilities. Primarily used to improve primary and/or tertiary treatment, the CoMag System easily integrates with planned or existing facilities, making it easier than ever to solve today’s operational and environmental challenges.

At the Concord WWTP, the CoMag System includes six steps:

  • Conventional chemical flocculation with Ferric, Alum or PAC
  • Infusion of the floc with fully inert, finely ground, nonabrasive magnetite
    (Fe3O4) to increase the specific gravity of the floc
  • Coagulation to bind the floc together
  • High rate clarification in traditional but smaller clarifiers
  • Sludge recycled for stable operation, upset prevention and pin floc capture
  • 99+% recycle and reuse of magnetite for low operating costs

Results

Installed in 2007, the CoMag® System exceeded all performance parameters — achieving TP down to 0.2 mg/L, with daily capacity of 1.25 (4.73)/4.4 (16.7) MGD(MLD).



The system now plays an integral role in a larger facility upgrade that includes improvements to the headworks, disinfection system, plant utilities, controls and other processes. Additionally, its high-quality effluent enables the facility to utilize smaller, more cost-effective UV disinfection system.​

Request a Proposal

Contact Evoqua for more information on available solutions

Request a Proposal
星空彩票外围权威网站_APP下载_安卓版/苹果版下载_(2024)_最新版 星空彩票真人权威公司_APP下载_安卓版/苹果版下载_(2024)_最新版 kaiyun·开云综合体育(官方)最大知名买球_APP下载_安卓版/苹果版下载_(2024)_最新版 开云综合体育(官方)真人网上盘口_APP下载_安卓版/苹果版下载_(2024)_最新版 最新靠谱kaiyun·开云综合体育(官方)导航_APP下载_安卓版/苹果版下载_(2024)_最新版 星空彩票靠谱体育盘口_APP下载_安卓版/苹果版下载_(2024)_最新版 靠谱风云(官方)足球入口_APP下载_安卓版/苹果版下载_(2024)_最新版 博鱼(官方)知名最火网_APP下载_安卓版/苹果版下载_(2024)_最新版 leyu·乐鱼综合体育(官方)最大外围官方_APP下载_安卓版/苹果版下载_(2024)_最新版 IM体育最新网上评级_APP下载_安卓版/苹果版下载_(2024)_最新版